Test de disco duro | Develop Site

smartctl 5.43 2012-06-30 r3573 [x86_64-linux-3.10.4-pmagic64] (local build) Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===

Model Family: Western Digital Scorpio Blue Serial ATA (Adv. Format)

Device Model: WDC WD3200BPVT-22JJ5T0

Serial Number: WD-WX31EA1RF584

LU WWN Device Id: 5 0014ee 2b15f5159

Firmware Version: 01.01A01

User Capacity: 320,072,933,376 bytes [320 GB]

Sector Sizes: 512 bytes logical, 4096 bytes physical

Device is: In smartctl database [for details use: -P show]

ATA Version is: 8

ATA Standard is: Exact ATA specification draft version not indicated

Local Time is: Fri May 11 07:18:50 2018 UTC

SMART support is: Available - device has SMART capability.

SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===

SMART overall-health self-assessment test result: PASSED

General SMART Values:

Offline data collection status: (0x00) Offline data collection activity was never started.

Auto Offline Data Collection: Disabled.

Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run.

Total time to complete Offline data collection: ( 7380) seconds.

Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 76) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x7035) SCT Status supported. SCT Feature Control supported. SCT Data Table supported.

SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x002f 181 168 051 Pre-fail Always - 391999 3 Spin_Up_Time 0x0027 145 134 021 Pre-fail Always - 1750 4 Start_Stop_Count 0x0032 055 055 000 Old_age Always - 45482 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0 7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0 9 Power_On_Hours 0x0032 063 063 000 Old_age Always - 27129 10 Spin_Retry_Count 0x0032 100 100 000 Old_age Always - 0 11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 096 096 000 Old_age Always - 4183 191 G-Sense_Error_Rate 0x0032 001 001 000 Old_age Always - 1664 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 219 193 Load_Cycle_Count 0x0032 001 001 000 Old_age Always - 1157125 194 Temperature_Celsius 0x0022 106 086 000 Old_age Always - 37 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0 197 Current_Pending_Sector 0x0032 001 001 000 Old_age Always - 65495 198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x0008 100 253 000 Old_age Offline - 0

SMART Error Log Version: 1 ATA Error Count: 19 (device log contains only the most recent five errors) CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 19 occurred at disk power-on lifetime: 21103 hours (879 days + 7 hours) When the command that caused the error occurred, the device was active or idle.

After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 08 40 e1 d2 e1 Error: UNC 8 sectors at LBA = 0x01d2e140 = 30597440

Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 08 40 e1 d2 e1 08 05:23:39.152 READ DMA ef 10 02 00 00 00 a0 08 05:23:39.152 SET FEATURES [Reserved for Serial ATA] ec 00 00 00 00 00 a0 08 05:23:39.150 IDENTIFY DEVICE ef 03 46 00 00 00 a0 08 05:23:39.150 SET FEATURES [Set transfer mode]

Error 18 occurred at disk power-on lifetime: 21103 hours (879 days + 7 hours) When the command that caused the error occurred, the device was active or idle.

After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 08 40 e1 d2 e1 Error: UNC 8 sectors at LBA = 0x01d2e140 = 30597440

Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 08 40 e1 d2 e1 08 05:23:36.563 READ DMA ef 10 02 00 00 00 a0 08 05:23:25.344 SET FEATURES [Reserved for Serial ATA] ec 00 00 00 00 00 a0 08 05:23:25.342 IDENTIFY DEVICE ef 03 46 00 00 00 a0 08 05:23:25.342 SET FEATURES [Set transfer mode]

Error 17 occurred at disk power-on lifetime: 21103 hours (879 days + 7 hours) When the command that caused the error occurred, the device was active or idle.

After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 08 38 e1 d2 e1 Error: UNC 8 sectors at LBA = 0x01d2e138 = 30597432

Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 08 38 e1 d2 e1 08 05:23:22.758 READ DMA ef 10 02 00 00 00 a0 08 05:23:22.758 SET FEATURES [Reserved for Serial ATA] ec 00 00 00 00 00 a0 08 05:23:22.756 IDENTIFY DEVICE ef 03 46 00 00 00 a0 08 05:23:22.756 SET FEATURES [Set transfer mode]

Error 16 occurred at disk power-on lifetime: 21103 hours (879 days + 7 hours) When the command that caused the error occurred, the device was active or idle.

After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 08 38 e1 d2 e1 Error: UNC 8 sectors at LBA = 0x01d2e138 = 30597432

Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 08 38 e1 d2 e1 08 05:23:20.173 READ DMA c8 00 08 30 e1 d2 e1 08 05:23:20.173 READ DMA c8 00 08 28 e1 d2 e1 08 05:23:20.172 READ DMA c8 00 08 20 e1 d2 e1 08 05:23:20.172 READ DMA c8 00 08 18 e1 d2 e1 08 05:23:20.172 READ DMA

Error 15 occurred at disk power-on lifetime: 21103 hours (879 days + 7 hours) When the command that caused the error occurred, the device was active or idle.

After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 08 00 da d2 e1 Error: UNC 8 sectors at LBA = 0x01d2da00 = 30595584

Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- c8 00 08 00 da d2 e1 08 05:23:13.190 READ DMA ef 10 02 00 00 00 a0 08 05:23:13.190 SET FEATURES [Reserved for Serial ATA] ec 00 00 00 00 00 a0 08 05:23:13.188 IDENTIFY DEVICE ef 03 46 00 00 00 a0 08 05:23:13.188 SET FEATURES [Set transfer mode]

SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed: read failure 90% 27016 18009920 # 2 Extended offline Completed: read failure 90% 27016 18009920 # 3 Short offline Completed: read failure 90% 18906 17352696 # 4 Extended offline Completed: read failure 90% 18386 7606312 # 5 Short offline Completed: read failure 90% 18383 7606312 # 6 Extended offline Completed: read failure 90% 18365 7606312 # 7 Short offline Completed: read failure 90% 18343 333784 # 8 Extended offline Completed: read failure 90% 18339 333776 # 9 Short offline Completed without error 00% 4 - #10 Short offline Completed without error 00% 4 -

SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.

Español